Case Study

Medical Waste Incinerator CO Removal — Field Test

Field test of CO oxidation catalyst performance on a medical waste pyrolysis / incineration exhaust stream.

Reported field test result — test date 2023-03-20

CO: 11,224.2 mg/Nm³ → 16.2 mg/Nm³

Reported result

The original field test record reports CO concentration reduced from 11,224.2 mg/Nm³ to 16.2 mg/Nm³ on 2023-03-20.

Derived removal efficiency

On the reported inlet/outlet pair, single-pass CO removal was 99.86% ((11,224.2 − 16.2) / 11,224.2). This is arithmetic on the recorded values — it is not a design guarantee, because the operating conditions behind the measurement are not published.

Data completeness note

For full engineering evaluation, the following data should be attached to the original record. A complete field-list and blank template are published in the Knowledge Center Field Test Report Template.

  • Gas flow rate
  • Operating temperature
  • Oxygen content
  • Continuous operating time
  • Detection method and instrument

What this case demonstrates

The test shows high CO conversion on a fluctuating incineration stream — evidence of the catalyst’s tolerance to thermal cycling and multi-pollutant conditions.

Engineering takeaways

The reported field data — CO reduced from 11,224.2 mg/Nm³ to 16.2 mg/Nm³ on 2023-03-20 — was measured on a medical waste incinerator, a stream that also carries HCl, SO₂, heavy metals and moisture. Catalyst survival in this duty depends on the upstream gas cleaning: the acid and particulate removal stages protect the catalyst from rapid poisoning and blinding.

For a permanent installation, the follow-up questions are the operating temperature at the catalyst position, the CO spike behaviour during batch charging, and the expected chloride exposure — all of which set the deactivation margin in the sizing calculation.

How this test is classified

This record is registered in the Knowledge Center Evidence Registry, which states its data type, verification status and the conditions not published.